Launch and activation permissions + Access Permissions + Configuration Permissions => added IIS_IUSRS + Network Service with Full Controll**Ĭhanged the build of the project that converts the. **1) Run dcomcnfg open Component ServicesĢ) Expand Component Services "->" Computer "->" My Computer "->" the DCOM configuration "ģ) Find the "Microsoft Excel application."Ĥ) Right to open the Properties dialog boxĦ) "Launch and Activation Permissions, configure permissions, have added permissions - Identity run under Adminstrator user (This User), Interactive User and Launching Usersħ). Things that I have tried on the staging server: The problem is that this error occurs only on the staging server on my local machine it works fine. Retrieving the COM class factory for component with CLSID failed due to the following error: 80080005 Server execution failed (Exception from HRESULT: 0x80080005 (CO_E_SERVER_EXEC_FAILURE)).Īt .AllocateUninitializedObject(RuntimeType objectType)Īt .ActivationServices.CreateInstance(RuntimeType serverType)Īt .ActivationServices.IsCurrentContextOK(RuntimeType serverType, Object props, Boolean bNewObj)Īt (RuntimeType type, Boolean publicOnly, Boolean noCheck, Boolean& canBeCached, RuntimeMethodHandleInternal& ctor, Boolean& bNeedSecurit圜heck)Īt (Boolean publicOnly, Boolean skipCheckThis, Boolean fillCache, StackCrawlMark& stackMark)Īt (Boolean publicOnly, Boolean skipCheckThis, Boolean fillCache, StackCrawlMark& stackMark)Īt (Type type, Boolean nonPublic)Īt (Type type) Periodically the C# app fails to open a workbook with the below error. I cycle through a lot open / close /compute cycles. It would appear it's the volume of autorecover files which is the root cause. TLDR the fix for me is to disable AutoRecover from File -> Options -> Save, Right click on Component Services/Computers/DCOM Config/Microsoft Word97 - 2003 Document "Login as Batch Job" privilege for "Run As." COM servers, butĪnyway I would suggest re-verifying this information for your (this page seems to suggest misspelled passwords or lacking the There is a security problem in the way the COM server is started.The COM server is currently stopping and there is a race conditionīetween CoCreateInstance and the COM server stopping part.The COM server doesn't register for the right class IDs.Start and fails to execute the CoRegisterClassObjects() in less than The machine has a high CPU load and the process takes a long time to.I found this article which talks more about this issue in depth If this helps,Įrror “80080005 Server execution failed (Exception from HRESULT: 0x80080005 (CO_E_SERVER_EXEC_FAILURE))” could occur due to following reasons: Well, stupidly enough, I forgot to write the code to close the interop application. This caused a memory issue which leaded to the exception from hresult 0x80080005 error. Open the properties, select Identity tab and select the interactive user.īUT - the problem came back every few minutes !Īfter hours of trying to figure out the cause, I noticed my server had hundreds of opened WINWORD.EXE processes. Open it and go to: Component Services -> Computers -> My Computer -> DCOM Config -> Microsoft Excel Application. Solution 2ĭoing the following did solve my problem: Open the properties, select Identity tab and select the interactive user. Component Services -> Computers -> My Computer -> DCOM Config -> Microsoft Excel Application.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |